Electrical
Load strategy, distribution, lighting verified in DIALux, and earthing and lightning protection studies that stand up to review.
An electrical package a utility reviewer, a contractor and a commissioning team can all work from.
Who this is for Contractors, industrial owners and infrastructure developers needing distribution, lighting or protection design.
Price this scopeWhat you receive
Load schedule and distribution strategy
Connected and demand load by board, with diversity stated, sized for the tariff and the supply the utility will actually give.
Single-line diagrams and panel schedules
Protection, discrimination and cable sizing shown together, so the diagram and the schedule cannot disagree.
Lighting design verified in DIALux
Illuminance, uniformity and glare checked against the task, with the calculation file issued alongside the layout.
Earthing and lightning protection study
Earth resistance, electrode arrangement and the protection zone worked to BS 7430 and NFPA 780, with the soil data stated.
Site-wide infrastructure
Networks, substations, street lighting and utility corridors, coordinated with the civil layout before excavation.
Containment and cable route layouts
Trays, trunking and busbar routed in the coordinated model with the pulling and access space drawn in.
The scope, at a glance
-
Load schedules
Load schedules, single-line diagrams (SLD) and panel schedules.
-
Power distribution
Distribution, cable sizing and voltage-drop calculations.
-
Lighting design
Lighting design and lux-level calculations verified in DIALux.
-
Earthing and lightning protection
Earthing and lightning protection to BS 7430 and IEC 62305.
-
Short-circuit and protection
Short-circuit studies and protective device coordination.
-
Low-current systems
Fire alarm, CCTV, access control, data, BMS and IPTV.
-
Standby and emergency power
Generators, UPS and automatic transfer switches.
-
SEC-compliant drawings
SEC-compliant connection drawings and MV/LV substations.
- Code-compliant IEC, BS, SEC and the local standards.
- Safe and reliable Engineered for safety, reliability and efficiency.
- Accurate and coordinated Documentation that cuts errors and rework.
- Integrated Power, lighting, protection and low-current under one roof.
Load strategy, distribution, lighting verified in DIALux, and earthing and lightning protection studies that stand up to review.
How it is produced
The supply constraint comes first
Design starts from what the utility will actually connect, because a scheme that assumes a bigger supply is a redesign waiting to happen.
Lighting is verified, not specified
Every space is calculated in DIALux against its task, and the report is issued so the numbers can be checked.
Protection is co-ordinated end to end
Discrimination is checked from the incomer to the final circuit, not assumed from a manufacturer’s table.
Written for the reviewer who signs it
Drawings and calculation notes are laid out in the format the utility and the authority expect, from the first issue.
Projects delivered under this service
4 projects

Al Amal Hospital
The densest ceiling void in construction, cleared before a hanger went up. Architecture, structure and MEP federated into one model, and…HealthcareAbha, KSA
Taya Industrial City
An industrial city's utility corridors, resolved before excavation. Site-wide electrical network design, street lighting verified in…InfrastructureRiyadh, KSA
SBF Factory
Factory buildings designed across architecture, structure, MEP and Civil Defense systems, with a coordinated IFC model and design visuals…IndustrialRiyadh, KSA
Qortoba Offices
Electrical design for an office building in Riyadh: power distribution from the ground-floor electrical rooms to every floor, modelled in…CommercialRiyadh, KSASoftware
- DIALux evo
- ETAP
- Revit MEP
- AutoCAD
- Excel calculation notes
Standards and codes
- NFPA 70 / NEC
- IEC 60364
- BS 7430
- NFPA 780
- SBC 401
- EN 12464
What the deliverable is
- DWG layouts
- Single-line diagrams
- Load schedules XLSX
- DIALux report PDF
- Calculation notes
Deliverables
Pick a discipline and tick what you need. Send the selection and its indicative budget range appears on screen and arrives in your inbox.
| Deliverables | Unit |
|---|---|
| Electrical design & lighting: commercial | per m² |
| Earthing & lightning protection study (BS 7430 / NFPA 780) | lump sum |
| DIALux lighting study | lump sum |
Questions clients ask
Do you issue the DIALux file or only the report?
Both. The native file goes with the report, so your team or a reviewer can rerun the calculation with different fittings.
Can you take a street-lighting scheme across a whole site?
Yes: the road network is modelled as a whole rather than street by street, which is what keeps the connected load down.
Who is responsible for the earthing design?
The engineer who produced the study signs it, and the soil data it relies on is stated on the front page so its basis is visible.

A question that is not here?
Ask the engineer who would run your project. Send the drawings and the answer comes back in writing.
Send us one package.
Send a package and you get a scope, a fixed price and a delivery date within two working days.
Related services
Mechanical
HVAC, plumbing and plant-room design balanced against comfort, code compliance and what the building will cost to run.
BIM coordination
A federated model, a clash register that closes, and coordinated sections issued per trade before installation starts.
Steel structures
Connection design, fabrication detailing and shop drawings a fabricator can put on the machine without redrawing them.